2D Symbologies Enter/Exit Programming Mode
Product Reference Guide
205
Micro PDF417 Set Length 2
This feature specifies one of the bar code lengths for Micro PDF417 Length Control. Length 2
is the maximum label length if in Variable Length Mode, or the second fixed
length if in Fixed
Length includes the bar code’s data characters only. Characters can be set from 0001 to 0366
characters (pad with zeroes) in increments of 01. Any value greater than 0366 will be considered
to be 0366.
See page 253 for detailed instructions on setting this feature.
$CMIL2
Select Micro PDF417 Length 2 Setting
To configure this feature, scan
the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at
left followed by the digits from the Alphanumeric
characters in
Appendix E, Keypad representing your
desired character(s). End by scanning the ENTER/EXIT
bar co
de again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
Length 2 is 0366 Characters