52 
 
REDUNDANCY 
LEVEL *  
Ensures integrity by setting the number of consecutive, identical decodes that are 
required for the bar code to be considered readable. For example, if set to three 
times, the bar code will not pass until the same values have been decoded three 
times in succession.  
 
The setting range is 1 – 6, and Auto.   
 
Notes: 
(1) Depending upon the print speed, higher verification levels may 
cause erroneous failures when scanning multiple bar codes or bar 
codes that are small in height.  
 
(2) When ‘Auto’ is selected, the printer defaults to a MIN READABLE 
HEIGHT setting of 1/16.  
 
2   Is the Default Setting. 
SET DEFAULTS 
* 
Resets the Scanner to the default values, as follows:   
Mode = Auto 
Barcode Count = 00   
Min Readable Height = Disabled 
Redundancy Level = 2  
 
RFID 
Controls the programming and verification of RFID tags, where:   
RFID MODULE 
Sets the mode of RFID operation: 
 
Note: 
If trying to enable RFID operation without option's presence (installed or 
detected), the printer will initially respond with a DISABLED message.   
 
DISABLED  Disables the option. 
HF  Selects the High Frequency RFID option. 
UHF MULTI-
PROTOCOL 
Selects the Ultra-High Frequency RFID option. 
RFID POSITION 
* 
(1.10 - 4.00 INCHES)   
1.10   Is the Default Setting.  
HF SETTINGS * 
Sets HF tag parameters: 
TAG TYPE  Sets the tag type: 
ISO 15693 
TI 
PHILIPS 
ST LRI512 
ST LRI64 
AFI VALUE  (00 - FF) 
AFI LOCK  ENABLED / DISABLED 
DSFID VALUE  (00 - FF) 
DSFID LOCK  ENABLED / DISABLED 
EAS VALUE  (00 - FF) 
AUDIO 
INDICATOR 
ENABLED / DISABLED 
ERASE ON 
FAULT 
ENABLED / DISABLED