LS10 Installation and Operating Guide Version 1.01
Appendix E. LS10 Remote Command API E-17 Document #: 9301H66300 Ver. 1.01
There are two levels of password protection in the LS10. The NetCmd Password will allow
access to the LS10 for Operator level type commands. The Setup Password allows access
to setup and configuration level commands. The commands in this document only require
the operator level password (if set).
The AUTH may be used for either the Operator or Setup level password.
Parameters:
[Password] NetCmd or Setup level password. The LS10 compares this first with
setup level password and gives Setup Level authorization if it
matches. Otherwise, it compares it to the NetCmd password and
authorizes operator commands if it matches.
SETUP The LS10 returns this value when Setup Level authorization has been
granted.
OP The LS10 returns this value when NetCmd Level authorization has
been granted.
SECERR The LS10 returns this value if neither Setup nor Operator level
authorization has been granted.
5. Serial Number
Command: @SERIALNO<CR>
Operation
Response: SERIALNO <space>SN<CR>
Read
Reads the LS10 serial number.
Parameters
SN This value is the serial number string that has been permanently
assigned to the LS10 unit.
6. MAC Address
Command: @MAC<CR>
Operation
Response: MAC<space>Mac adr<CR>
Read
Reads the LS10 network MAC address.
Parameters
Mac adr This is the 12 digit LS10 network interface MAC address.
Example
Send: @MAC<cr>
Receive: MAC 080077124578<cr>