6.7.3 ENGINE RUNNING
In manual mode, the load is not transferred to the generator unless a ‘loading request’ is made.
A loading request can come from a number of sources.
• Pressing the transfer to generator button.
• Request from DSE8x60 mains controller or from another DSE8x10 controller over the MSC link.
• Activation of an auxiliary input that has been configured to remote start on load
• Activation of the inbuilt exercise scheduler if configured for ‘on load’ runs.
NOTE:-The load transfer signal remains inactive until the Oil Pressure has risen. This prevents
excessive wear on the engine.
If the common bus is measured to be ‘dead bus’, the load breaker is closed.
If the bus is measured to be ‘live bus’, synchronising takes place before the breaker is closed.
Once the load has been transferred to the generator, the load switch will not be automatically opened unless:
• Press the Open Generator button (DSE8810 only)
• Press the auto mode button to return to automatic mode.
6.7.4 STOPPING SEQUENCE
In manual mode the set will continue to run until either :
• The stop button
is pressed – The set will immediately stop
• The auto button is pressed. The set will observe all auto mode start requests and stopping timers
before beginning the Auto mode stopping sequence.