Front Panel Configuration
97
9.1.2 ADJUSTABLE PARAMETERS
Section
Parameter
Detail of Parameter
Parameter Action
Values
Inputs
Oil Pressure Low Oil Pressure Shutdown Trip 0.00 Bar
Warning Trip 0.00 Bar
Coolant Temperature High Coolant Alarms Pre-Alarm Trip 00 Deg C
Electrical Trip 00 Deg C
Shutdown Trip 00 Deg C
Low Coolant Alarms Pre Alarm Trip 00 Deg C
Fuel Level Fuel Usage Alarm Running Rate Up / down
Stopped Rate Up / down
Timers
Start Timers Start Delay Remote Start Off Load s
Remote start On Load s
Telemetry Start s
Start Timers Preheat s
Cranking Time s
Crank Rest Time s
Smoke Limit s
Smoke Limit Off s
Safety on Delay s
Warming up Timer s
Stopping Timers Stopping Timers Return Delay s
Cooling Time mm:ss
Fail To Stop Delay 0s
Gen Transient Delay 0s
Display Page Timer mm: ss
Scroll Timer s
Generator
Generator Options AC System
3 Phase, 4 wire Delta
2 Phase, 3 Wire L1-L3
2 Phase, 3 Wire L1-L2
3 Phase, 3 Wire
Single Phase, 2 Wire
3 Phase, 4 Wire
Generator Rating KW Rating 0 KW
kVAr Rating 0 kVAr
Generator Current Current Options CT Primary (L1,L2,L3,N) 0A
CT Secondary 5Amp / 1 Amp 5 / 1 Amp
Full Load Rating 0A
Earth Fault Earth CT Primary 0A
Trip Action Enabled / Disabled
Trip Percentage 0%
Over Current Alarm IDMT Alarm Enabled / Disabled
Trip 0% 0.0A
Short Circuit Trip 0% 0.0A
Generator Voltage Under Voltage Alarms Alarm Trip 0%
Pre-Alarm Trip 0A
Nominal Voltage Nominal Voltage 0V
Over Voltage Alarms Pre-alarm ttrip 0V
Alarm Trip 0V
Generator Frequency Under Frequency Alarms Alarm Trip
Pre-Alarm Trip
0.0Hz
0.0Hz
Nominal Frequency Nominal Frequency 0.0Hz
Pre-Alarm Trip
Alarm Trip
0.0Hz
0.0Hz
Generator Power Overload Protection Overload Protection Trip 0% (0 kW)
Reverse Power Trip (Delay) 0kW (0.0 s)
Synchronising Load Control
Reactive Load Mode
KVAr Fixed Export
kVAr Share
None
Ramp Speed Ramp Speed 0.0 %/s
Load Demand Calling For More Sets 0 %
Calling For Less Sets 0 %
Insufficient Capacity Action
Warning / Shutdown / None
/ Indication / Electrical Trip
Engine
Engine Options Overspeed Options Overspeed Overshoot 0%
Overshoot Delay s
Droop Enable Enabled / Disabled
Percent 0.0%
Speed Settings Under Speed Alarm Enable Enabled / Disabled
Alarm Trip 0000 RPM
Warning Enable Enabled / Disabled
Warniing Trip 0000 RPM
Over Speed Alarm Trip 0000 RPM
Pre-Alarm Enable Enabled / Disabled
Pre-Alarm Trip 0000 RPM
Plant Battery Under Voltage Alarms Under Volts Enable Enabled / Disabled
Under Volts Delay mm:ss
Under Volts Pre-Alarm 0.0v
Over Voltage Alarms Over Volts Enable Enabled / Disabled
Over volts Delay mm:ss
Over Volts Pre-Alarm 0.0v
Charge Alt Alarm Alarm Enable Enabled / Disabled
Alarm Trip 0.0v
Alarm Delay s
Charge Alt Pre-Alarm Pre-Alarm Enable Enabled / Disabled
Pre-Alarm Trip 0.0v
Pre-Alarm Delay s
Alt. Config Options
Default Configuration
Alternative Configuration 3
Alternative Configuration 2
Alternative Configuration 1
Main Configuration
9.2 ACCESSING THE ‘MAINTENANCE’ CONFIGURATION EDITOR

Table of Contents

Other manuals for Deep Sea Electronics Plc DSE8810

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Deep Sea Electronics Plc DSE8810 and is the answer not in the manual?

Deep Sea Electronics Plc DSE8810 Specifications

General IconGeneral
BrandDeep Sea Electronics Plc
ModelDSE8810
CategoryController
LanguageEnglish

Related product manuals