V0817, 5.9
5.2.5. Corrections
In this view mode all corrections of all bends are shown. You can browse through all
corrections and change them as you see fit. If a correction for
1 is entered then this value is,
dependent on the settings parameter 'Angle correction programming', copied to the correction
for
2, or keeping the delta between both corrections, or not influencing the correction for 2.
Different corrections for
2 can be entered in the field itself.
The column 'Stored correction' is only available when the Angle correction database has been
activated. When activated, the column 'Stored correction' shows for each bend the correction
value that is present in the database. A blank entry in this column means the database does
not have a correction value for this type of bend. When a new correction is entered, it will be
copied to the database automatically.
The markers '>' indicate bends that have the same value.
All From Stored serves to copy corrections in the database to the current program: corrections
in all bends are adjusted according to database values.