V0817, 7.18
7.6. Default values
Y opening default
Default Y-axis opening, used as initial value for the parameter 'opening' in a new
program.
Default pressing speed
Default pressing speed, used as initial value for the parameter 'speed' in a bend
program.
Default decompression speed
Default decompression speed, used as initial value for the parameter 'decompression
speed' in a bend program.
Default wait for retract
Default value for the parameter 'wait for retract' in a bend program. This parameter
determines the control behaviour in a bend program.
Default step change code
Default value for the parameter 'step change code' in a bend program. This parameter
determines the moment of step change in a bend program.
The step change codes have been explained in more detail in the Program mode.
Default delay time
During the postprocessing, the waiting time of the X-axis at step change is set to zero.
With this parameter you can preset a longer waiting time when needed for product
handling.