V0817, 4.6
Force
Maximum adjusted force during pressing (automatically computed).
Dwell time
Holding time of punch at bending point.
Decompression
Decompression distance after the bending to release the working pressure from the
system.
4.2.3. Speed
Speed
Working speed (pressing speed). Initially, the value for this parameter is copied from the
parameter Default Pressing Speed in the Settings mode.
Decomp speed
The decompression speed is the programmable speed of the beam during the
decompression distance.
4.2.4. Functions
Repetition
0 = bending is skipped
1 through 99 = the number of times this bending will be repeated.
Wait for retract
In case of a retract, let the Y-axis wait until the retract is finished, yes or no.
No: the retract is started when the Y-axis passes the clamping point, the Y-axis does not
stop.
Yes: when the Y-axis reaches the clamping point, the Y-axis is stopped and the retract
is started. When the retract is completed, the Y-axis moves on.
Code
Programmable step change code parameter which determines when the parameter
values for the next bending will be active. The following settings are possible:
0 = ER: Bending number change (step change) at end of decompression (next bend
parameters active).
1 = MUTE: Step change at muting position when the beam moves in opening direction.
2 = UDP: Step change at upper dead point.
3 = UDP STOP: Step change at upper dead point without movement of any axis and the
control goes to "stop".
4 = EXTERNAL: Step change if C-input signal becomes active, without movement of the
beam. When you still have a beam movement there will be no retract function of the
back gauge performed. See also code 5.
5 = UDP EXTERNAL: Step change if C-input signal becomes active and the beam is in
the upper dead point. Now you may move the beam and the retract function of the
back gauge will be performed.
Delay time
Programmable delay time before step change (0-30sec)