V0817, 4.5
Product position
The absolute position value of the product in the Z-direction. Left machine side is
reference position zero.
Angle
The required angle of this bend. This parameter only appears if angle programming is
selected with the parameter 'Angle sel.' and the bend method is an air bend.
Hem opening
The hem bend can be made with a certain opening distance between the 2 flanges. The
hem opening value will be used calculating the beam position in the hemming process.
By default this parameter has the value of the Settings mode parameter Default Hem
Opening.
Y-axis (Bend position)
The required Y-axis position for this bend. This parameter only appears if absolute
programming is selected with the parameter 'Angle sel.' This parameter also appears if
the bend method is bottoming and/or hemming.
Mute
Sequence point at which the Y-axis is switched from fast closing speed to pressing
speed. The value programmed here is the distance of the mute point above the sheet.
By default, the mute value from the programmed die is used.
Whether or not this parameter is present depends on machine settings.
Parallel
Difference of left- and right hand side cylinder (Y1 and Y2). When positive, right hand
side lower. When negative, right hand side higher. The programmed value is active
below the clamping point.
Opening
This parameter results in a certain gap opening between the punch and the die after the
bend. A positive value is the gap opening above Mute, a negative value below Mute.
When you want to limit the handling time of the product you can program a small
positive or a negative value.
4.2.2. Force