V0817, 7.16
comparison. If the angle is the same as the angle of the active bend, the correction is
offered. If the angle of the active bend has a maximum difference of 10° with two
adjacent bends, a correction is interpolated from these two bends. If the difference of
the corrections of the two adjacent bends is more than 5°, there will be no correction
offered.
Initial angle correction
To program relative small angle corrections the initial correction database is available.
This parameter is independent on the parameter "Angle correction database".
The initial correction is only visible and programmable on the corrections page in
Automatic mode and Manual mode. On the main page in Automatic mode and Manual
mode the initial correction is not visualized. The total correction is the sum of the
visualized correction and the initial correction.
Example:
- Program an angle correction of -8 degrees.
- Program an initial correction of -6 degrees. Now the total correction
remains unchanged: the visualized correction is changed from -8 degrees
to -2 degrees.
disabled => no initial angle corrections programmable.
enabled => initial angle corrections programmable on the corrections page
General angle correction programming
To program general angle corrections which are used in all bends of the program.
These angle corrections are not related to specific bend angles and therefore not stored
in the angle correction database.
disabled => no general angle corrections.
enabled => only G-corr.
1.
1 and 2=> G-corr. 1 and G-corr. 2.
Manual mode store angle corrections
To enable the storage of angle corrections programmed in Manual mode. Corrections
can be derived from bend results in Manual mode which later can be used during
product programming.
Angle correction programming
Parameter to switch between copying or keeping the delta values or changing
independently when changing angle corrections in production mode.
copy => copy C
1 to C2 when changing C1.
delta => keep delta between C
1 and C2 when changing C1.
independent => change C
1 and C2 independently.
X correction programming
Parameter to switch between copying or keeping the delta values or changing
independently when changing the X-axis corrections in production mode.
copy => copy CX1 to CX2 when changing CX1.
delta => keep delta between CX1 and CX2 when changing CX1.
independent => change CX1 and CX2 independently.
Only available when an X2-axis is present.