Control and Monitoring | 103
Command
History
E-Series Example
Figure 5-10. Command Example: show alarms on E-Series
show chassis
c e
View the configuration and status of modules in the system. Use this command to determine the
chassis mode.
Syntax
show chassis [brief]
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
E-Series original Command
FTOS# show alarms
-- Minor Alarms --
Alarm Type Duration
----------------------------------------------------
RPM 0 PEM A failed or rmvd 7 hr, 37 min
SFM 0 PEM A failed or rmvd 7 hr, 37 min
SFM 1 PEM A failed or rmvd 7 hr, 37 min
SFM 2 PEM A failed or rmvd 7 hr, 37 min
SFM 3 PEM A failed or rmvd 7 hr, 37 min
SFM 4 PEM A failed or rmvd 7 hr, 37 min
SFM 5 PEM A failed or rmvd 7 hr, 37 min
SFM 6 PEM A failed or rmvd 7 hr, 37 min
SFM 7 PEM A failed or rmvd 7 hr, 36 min
line card 1 PEM A failed or rmvd 7 hr, 36 min
line card 4 PEM A failed or rmvd 7 hr, 36 min
only 8 SFMs in chassis 7 hr, 35 min
-- Major Alarms --
Alarm Type Duration
----------------------------------------------------
No major alarms
FTOS#
brief (OPTIONAL) Enter the keyword brief to view a summary of the show chassis output.
Version 8.1.1.0 Introduced on E-Series ExaScale