Remote Monitoring (RMON) | 1261
Example 2
Figure 49-7. show rmon hc-alarm index Command Example
show rmon history
c e s
Display the contents of the RMON Ethernet History table.
Syntax
show rmon history [index] [brief]
Parameters
Defaults
No default behavior
Command Modes
EXEC
Command
History
Example 1
Figure 49-8. show rmon history index Command Example
FTOS#show rmon hc-alarm 1
RMON high-capacity alarm entry 1
object: 1.3.6.1.2.1.1.3
sample interval: 5
sample type: absolute value.
value: 185638
alarm type: rising or falling alarm.
alarm rising threshold value: positive.
rising threshold: 1001, RMON event index: 1
alarm falling threshold value: positive.
falling threshold: 999, RMON event index: 6
alarm sampling failed 0 times.
alarm owner: 1
alarm storage type: non-volatile.
alarm status: OK
FTOS#
index
(OPTIONAL) Enter the table index number to display just that entry.
brief (OPTIONAL) Enter the keyword brief to display the RMON Ethernet
History table in an easy-to-read format.
Version 7.6.1.0 Support added for S-Series
Version 6.1.1.0 Introduced for E-Series
FTOS#show rmon history 6001
RMON history control entry 6001
interface: ifIndex.100974631 GigabitEthernet 2/0
bucket requested: 1
bucket granted: 1
sampling interval: 5 sec
owner: 1
status: OK
FTOS#