1446 | Uplink Failure Detection (UFD)
www.dell.com | support.dell.com
clear ufd-disable
s S50 only
Re-enable one or more downstream interfaces on the switch/router that are in a UFD-disabled error
state so that an interface can send and receive traffic.
Syntax
clear ufd-disable {interface interface | uplink-state-group group-id}
Parameters
Defaults
A downstream interface in an uplink-state group that has been disabled by UFD is disabled and in a
UFD-disabled error state.
Command Modes
CONFIGURATION
Command
History
Related
Commands
interface interface Specifies one or more downstream interfaces.
For interface, enter one of the following interface types:
Fast Ethernet: fastethernet {slot/port | slot/port-range}
1-Gigabit Ethernet: gigabitethernet {slot/port |slot/port-range}
10-Gigabit Ethernet: tengigabitethernet {slot/port |slot/port-range}
Port channel: port-channel {1-512 | port-channel-range}
Where port-range and port-channel-range specify a range of ports
separated by a dash (-) and/or individual ports/port channels in any
order; for example:
gigabitethernet 1/1-2,5,9,11-12
port-channel 1-3,5
A comma is required to separate each port and port-range entry.
uplink-state-group
group-id
Re-enables all UFD-disabled downstream interfaces in the group.
Valid group-id values are 1 to 16.
Version 8.4.2.3 Introduced on the S-Series S50.
downstream
Assign a port or port-channel to the uplink-state group as a downstream
interface.
uplink-state-group
Create an uplink-state group and enabling the tracking of upstream
links.