Loading...
Uplink Failure Detection (UFD) | 1453
uplink-state-group
s S50 only
Create an uplink-state group and enabling the tracking of upstream links on a switch/router.
Syntax
uplink-state-group group-id
Parameters
Defaults
None
Command Modes
CONFIGURATION
Command
History
Usage
Information
After you enter the command, you enter uplink-state-group configuration mode to assign upstream and
downstream interfaces to the group.
An uplink-state group is considered to be operationally up if at least one upstream interface in the
group is in the link-up state.
An uplink-state group is considered to be operationally down if no upstream interfaces in the group are
in the link-up state. No uplink-state tracking is performed when a group is disabled or in an
operationally down state.
To delete an uplink-state group, enter the no uplink-state-group group-id command.
To disable upstream-link tracking without deleting the uplink-state group, enter the no enable
command in uplink-state-group configuration mode.
Related
Commands
Example
Figure 60-4. uplink-state-group Command Example
group-id
Enter the ID number of an uplink-state group. Range: 1-16.
Version 8.4.2.3 Introduced on the S-Series S50.
show running-config
uplink-state-group
Display the current configuration of one or more uplink-state groups.
show uplink-state-group
Display status information on a specified uplink-state group or all
groups.
FTOS(conf)#uplink-state-group 16
FTOS(conf)#
02:23:17: %RPM0-P:CP %IFMGR-5-ASTATE_UP: Changed uplink state group Admin state
to up: Group 16