Loading...
Uplink Failure Detection (UFD) | 1451
Related
Commands
show uplink-state-group
s S50 only
Display status information on a specified uplink-state group or all groups.
Syntax
show uplink-state-group [group-id] [detail]
Parameters
Defaults
None
Command Modes
EXEC
EXEC Privilege
Command
History
show uplink-state-group
Display status information on a specified uplink-state group or all
groups.
uplink-state-group
Create an uplink-state group and enabling the tracking of upstream
links.
group-id Displays status information on a specified uplink-state group or all
groups. Valid group-id values are 1 to 16.
detail Displays additional status information on the upstream and
downstream interfaces in each group
Version 8.4.2.3 Introduced on the S-Series S50.