610 | Interfaces
www.dell.com | support.dell.com
Tx Power  Present Tx power of the SFP. If this crosses Tx power alarm/warning 
thresholds, then the Tx power high alarm/warning flag is set to true. If it falls 
below the low alarm/warning thresholds, then the Tx power low alarm/
warning flag is set to true.
Rx Power  Present Rx power of the SFP. This value is either average Rx power or 
OMA.This depends upon on the Rx Power measurement type displayed 
above. If this crosses Rx power alarm/warning thresholds, then the Rx power 
high alarm/warning flag is set to true. If it falls below the low alarm/warning 
thresholds, then the Rx power low alarm/warning flag is set to true.
Data Ready state Bar This field indicates that the transceiver has achieved power up and data is 
ready. This is set to true if data is ready to be sent, false if data is being 
transmitted.
Rx LOS state  This is the digital state of the Rx_LOS output pin.This is set to true if the 
operating status is down.
Tx Fault state  This is the digital state of the Tx Fault output pin.
Rate Select state  This is the digital state of the SFP rate_select input pin.
RS state This is the reserved digital state of the pin AS(1) per SFF-8079 and RS(1) per 
SFF-8431.
Tx Disable state  If the admin status of the port is down then this flag will be set to true.
Temperature High Alarm Flag This can be either true/False and it depends on the Current Temperature value 
displayed above. 
Voltage High Alarm Flag This can be either true or false, depending on the Current voltage value 
displayed above.
Tx Bias High Alarm Flag  This can be either true or false, depending on the present Tx bias current value 
displayed above.
Tx Power High Alarm Flag  This can be either true or false, depending on the Current Tx power value 
displayed above.
Rx Power High Alarm Flag  This can be either true or false, depending on the Current Rx power value 
displayed above.
Temperature Low Alarm Flag  This can be either true or false, depending on the Current Temperature value 
displayed above.
Voltage Low Alarm Flag  This can be either true or false, depending on the Current voltage value 
displayed above.
Tx Bias Low Alarm Flag This can be either true or false, depending on the Tx bias current value 
displayed above.
Tx Power Low Alarm Flag  This can be either true or false, depending on the Current Tx power value 
displayed above.
Rx Power Low Alarm Flag  This can be either true or false, depending on the Current Rx power value 
displayed above.
Temperature High Warning 
Flag 
This can be either true or false, depending on the Current Temperature value 
displayed above.
Voltage High Warning Flag  This can be either true or false, depending on the Current voltage value 
displayed above.
Tx Bias High Warning Flag  This can be either true or false, depending on the Tx bias current value 
displayed above.
Table 23-10.  Diagnostic Data in show interfaces transceiver  (continued)
Line Description