EasyManuals Logo

Dell SCv3000 Deployment Guide

Dell SCv3000
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
(Four port HBA only) IPv4 address for storage controller module 1: port 3 ___ . ___ . ___ . ___
(Four port HBA only) IPv4 address for storage controller module 2: port 3 ___ . ___ . ___ . ___
Table 10. iSCSI Fault Domain 2
Target IPv4 address ___ . ___ . ___ . ___
Subnet mask ___ . ___ . ___ . ___
Gateway IPv4 address ___ . ___ . ___ . ___
IPv4 address for storage controller module 1: port 2 ___ . ___ . ___ . ___
IPv4 address for storage controller module 2: port 2 ___ . ___ . ___ . ___
(4-port HBA only) IPv4 address for storage controller module 1: port 4 ___ . ___ . ___ . ___
(4-port HBA only) IPv4 address for storage controller module 2: port 4 ___ . ___ . ___ . ___
Additional Storage Center Information
The Network Time Protocol (NTP) and Simple Mail Transfer Protocol (SMTP) server information is optional. The proxy server information is
also optional, but it may be required to complete the
Discover and Congure Uninitialized Storage Centers wizard.
Table 11. NTP, SMTP, and Proxy Servers
NTP server IPv4 address ___ . ___ . ___ . ___
SMTP server IPv4 address ___ . ___ . ___ . ___
Backup SMTP server IPv4 address ___ . ___ . ___ . ___
SMTP server login ID ________________
SMTP server password ________________
Proxy server IPv4 address ___ . ___ . ___ . ___
Fibre Channel Zoning Information
For a storage system with Fibre Channel front-end ports, record the physical and virtual WWNs of the Fibre Channel ports in Fault Domain
1 and Fault Domain 2. This information is displayed on the Review Front-End page of the Discover and Congure Uninitialized Storage
Centers wizard. Use this information to congure zoning on each Fibre Channel switch.
Table 12. Physical WWNs in Fault Domain 1
Physical WWN of storage controller 1: port 1 ________________
Physical WWN of storage controller 2: port 1 ________________
(4-port HBA only) Physical WWN of storage controller 1: port 3 ________________
(4-port HBA only) Physical WWN of storage controller 2: port 3 ________________
100 Worksheet to Record System Information

Table of Contents

Other manuals for Dell SCv3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell SCv3000 and is the answer not in the manual?

Dell SCv3000 Specifications

General IconGeneral
HDD speed10000 RPM
Storage drive size3.5 \
Storage drive capacity900 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Storage drives installedYes
Installed storage drive typeHDD
Total installed storage capacity6.3 TB
Maximum supported storage capacity- TB
Number of storage drives installed7
Number of storage drives supported16
USB connectivity-
Chassis typeRack (3U)
Product colorBlack, Grey
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power supply unit (PSU) capacity1485 W
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 80 %
Dell E-Value CodeSCv3000FC
Weight and Dimensions IconWeight and Dimensions
Depth785 mm
Width445 mm
Height133.3 mm