EasyManuals Logo

Dell SCv3000 Deployment Guide

Dell SCv3000
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
Novell Netware
Servers running Novell Netware require that the portdown value be recongured to allow enough time for the storage systems to fail over.
To the end of the Fibre Channel driver load line of nwserver/startup.ncf add :
/LUNS /ALLPATHS /ALLPORTS /PORTDOWN=60
Red Hat Enterprise Linux
Timeout values determine the time a server waits before destroying a connection after losing connectivity. With a single-path conguration
that value should be set to 60 seconds to allow the WWN of the failed port to transfer to a port on the other storage system. With a
multipath conguration the timeout value should be set to 5 seconds because the ports will fail over immediately. Congure the timeout
values as shown below based on the manufacturer of the HBA card and the path conguration.
Version 5.x
Congure these timeout values for servers running RHEL version 5.x. The settings vary based on the manufacturer of the HBA card.
Add one of these settings to the end of the le /etc/modprobe.conf based on the manufacturer of the HBA card.
Qlogic HBA Settings
Path
Conguration Timeout Setting
Single Path options qla2xxx qlport_down_retry=60
Multipath options qla2xxx qlport_down_retry=5
Emulex HBA Settings
Path
Conguration Timeout Setting
Single Path options lpfc lpfc_devloss_tmo=60
Multipath options lpfc lpfc_devloss_tmo=5
Version 6.x
Changing HBA settings in RHEL version 6.x requires the creation of a new conguration le that contains the settings in the table below.
For Qlogic HBA cards, create a conguration le in /etc/modprobe.d/ named qla2xxx.conf that contains one of the following parameters.
Qlogic HBA Settings
Path
Conguration Timeout Setting
Single Path options qla2xxx qlport_down_retry=60
Multipath options qla2xxx qlport_down_retry=5
For Emulex HBA cards, create a conguration le in /etc/modprobe.d/ named lpfc.conf that contains one of the following parameters.
106
HBA Server Settings

Table of Contents

Other manuals for Dell SCv3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell SCv3000 and is the answer not in the manual?

Dell SCv3000 Specifications

General IconGeneral
HDD speed10000 RPM
Storage drive size3.5 \
Storage drive capacity900 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Storage drives installedYes
Installed storage drive typeHDD
Total installed storage capacity6.3 TB
Maximum supported storage capacity- TB
Number of storage drives installed7
Number of storage drives supported16
USB connectivity-
Chassis typeRack (3U)
Product colorBlack, Grey
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power supply unit (PSU) capacity1485 W
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 80 %
Dell E-Value CodeSCv3000FC
Weight and Dimensions IconWeight and Dimensions
Depth785 mm
Width445 mm
Height133.3 mm

Related product manuals