Table 20. Citrix XenServer HBA Settings for Version 6.5 and Later
Field Setting
dev_loss_tmo 60
Microsoft Windows Server
Double-check that the timeout value for a Microsoft Windows Server is set to 60 seconds.
Make sure that the TimoutValue is set to 60 in the following Registry Editor location.
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Disk
NOTE: It is recommended that the latest service pack be installed prior to installing the clustering service.
Microsoft MPIO Settings
The following settings are recommended for Microsoft Windows Servers with MPIO installed.
Recommended MPIO Registry Settings
Congure the MPIO registry settings in the following registry location:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\services\mpio\Parameters
Table 21. MPIO Registry Settings
Field Setting
PDORemovePeriod 120
PathRecoveryInterval 25
UseCustomPathRecoveryInterval 1
Recommended iSCSI Initiator Settings
Congure the iSCSI initiator settings in the following registry location:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}\<Instance Number>
\Parameters
Table 22. iSCSI Initiator Settings
Field Setting
MaxRequestHoldTime 90
LinkDownTime 35
EnableNOPOut 1
HBA Server Settings 105

Table of Contents

Other manuals for Dell SCv3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell SCv3000 and is the answer not in the manual?

Dell SCv3000 Specifications

General IconGeneral
HDD speed10000 RPM
Storage drive size3.5 \
Storage drive capacity900 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Storage drives installedYes
Installed storage drive typeHDD
Total installed storage capacity6.3 TB
Maximum supported storage capacity- TB
Number of storage drives installed7
Number of storage drives supported16
USB connectivity-
Chassis typeRack (3U)
Product colorBlack, Grey
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power supply unit (PSU) capacity1485 W
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 80 %
Dell E-Value CodeSCv3000FC
Weight and Dimensions IconWeight and Dimensions
Depth785 mm
Width445 mm
Height133.3 mm