Chapter 7 Servo Parameters ASDA-B2
7-6 Revision September 2013
P1-40▲ VCM
Max. Analog Speed Command
or Limit
rated r/min O O 6.3.4
P1-41▲ TCM
Max. Analog Torque Command
or Limit
100 % O O O -
P1-76 AMSPD
Max. Rotation Speed of Encoder
Output
5500 r/min O O O -
Explanation of symbols (marked after parameter)
(★) Read-only register.
(▲) Parameter cannot be set when Servo On (when the servo drive is enabled).
() Parameter is effective only after the servo drive is restarted (after switching power off and
on).
() Parameter setting values are not retained when power is off.
Torque Control
Parameter Name Function Default Unit
Control Mode
Related
Section
PT S T
P1-01 CTL
Control Mode and Output
Direction
0
pulse
r/min
N-M
O O O 6.1
P1-02▲ PSTL Speed and Torque Limit 0 N/A O O O 6.6
P1-46▲ GR3 Encoder Output Pulse Number 1 pulse O O O -
P1-55 MSPD Maximum Speed Limit rated r/min O O O -
P1-09
~
P1-11
SP1~3 1st ~ 3rd Speed Limit
1000
~
3000
r/min O O 6.6.1
P1-12
~
P1-14
TQ1~3 1st ~ 3rd Torque Command 100 % O O O 6.4.1
P1-40▲ VCM
Max. Analog Speed Command
or Limit
rated r/min O O -
P1-41▲ TCM
Max. Analog Torque Command
or LImit
100 % O O O 6.4.4
Explanation of symbols (marked after parameter)
(★) Read-only register.
(▲) Parameter cannot be set when Servo On (when the servo drive is enabled).
() Parameter is effective only after the servo drive is restarted (after switching power off and
on).
() Parameter setting values are not retained when power is off.