Chapter 7 Servo Parameters ASDA-B2
7-90 Revision September 2013
Display
Format:
Decimal
Settings:
Refer to P4-11 for explanation.
Please note that when P2-08 is set to 10, the users cannot reset this parameter.
P4-17
COF3
Current Detector Drift Adjustment (W1 phase)
Address: 0422H
0423H
Operation
Interface:
Keypad / Software Communication
Related Section: N/A
Default: Factory setting
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 32767
Data Size: 16-bit
Display
Format:
Decimal
Settings:
Refer to P4-11 for explanation.
Please note that when P2-08 is set to 10, the users cannot reset this parameter.
P4-18
COF4
Current Detector Drift Adjustment (W2 phase)
Address: 0424H
0425H
Operation
Interface:
Keypad / Software Communication
Related Section: N/A
Default: Factory setting
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 32767
Data Size: 16-bit
Display
Format:
Decimal
Settings:
Refer to P4-11 for explanation.
Please note that when P2-08 is set to 10, the users cannot reset this parameter.
P4-19
TIGB IGBT NTC Calibration
Address: 0426H
0427H
Operation
Interface:
Keypad / Software Communication
Related Section: N/A
Default: Factory setting
Control
Mode:
ALL
Unit: N/A
Range: 1 ~ 3
Data Size: 16-bit