EasyManua.ls Logo

Desoutter CVIC - Page 31

Desoutter CVIC
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6159932010-09
31 / 60
English
CVIC - MODCVIC - MULTICVIC
Press .
Motor settings: «MOTOR PARAM.»
Thread Right/Left.
Speed rotational speed: 0 - 100 %.
Acceler 0 - 20 s. Acceleration or deceleration time to switch from one speed to another. This
parameter is enabled for the first phase and when the interphase time is not equal to zero.
When the interphase time is equal to zero, acceleration is optimised automatically.
Reset The Reset function allows you to reset the torque and/or angle values at the beginning of the current
phase.
External stop Yes/No The following conditions must be met for the system to stop the current phase and
shift to the next one:
- the «External stop» parameter must be on «yes» in this screen.
- the signal at the «External stop» input of the Input/Output connector must shift to «1».
Detailed RP. See tightening strategies (torque, torque + angle, angle + torque and prevailing torque) in
Appendix .
Jump phase (H)
This phase allows you to design more sophisticated cycles.
For example: D F1 V1 F2 F3 J1
D run down speed phase.
F1 final speed.
V1 action on NOK: - if NOK, jump to phase 6 (F3).
- otherwise, run phase F2 then stop the cycle.
empty phase: the cycle is stopped.
F3 SCY phase in case of NOK on phase 2.
J1 jump to phase 4 (F2) to finish.
No phase RP.
Prevailing Torque Phase (H)
This phase allows you to monitor the load moment (prevailing torque) of a screw or nut.
The initial timeout (expressed in time or angle) allows you to eliminate the shock pulse when starting the motor
and the mechanism.
Max.time Phase running timeout: 0.01 - 99 s.
Int.time time programmed between this phase and the next one: 0 - 20 s.
Target A target angle: 0 - 9999°.
Min T minimum torque: 0 to max. value of the spindle.
Max T maximum torque: 0 to max. value of the spindle.
Safety T saftey torque: 0 to max. value of the spindle.
Start typ type of start: time/angle.
Rot.angl.
or Rot.time angle or rotation time: 0-9999 degrees or 0 - 20 s.
Directio direction: Right/Left.
Speed rotational speed: 0 - 100 %.
Accelerat 0 - 20 s.
Reset: A angle: Yes / No
Reset: T torque: Oui / Non
External stop Yes/No The following conditions must be met for the system to stop the current phase and
shift to the next one:
- the «External stop» parameter must be on «yes» in this screen.
- the signal at the «External stop» input of the Input/Output connector must shift to «1».
Detailed RP. See tightening strategies (torque, torque + angle, angle + torque and prevailing torque) in
Appendix .

Table of Contents

Related product manuals