6159932010-09
48 / 60
English
CVIC-MODCVIC-MULTICVIC
According to the various combinations, the following characters will be obtained:
@ accept torque accept angle
A min. torque accept angle
B max. torque accept angle
D accept torque min. angle
E min. torque min. angle
F max. torque min. angle
H accept torque max. angle
I min. torque max. angle
J max. torque max. angle
Example of result:
A001001BZ@92120811021500041.7500121<CR><LF><LF><LF>
PC4 FORMAT:
Title
Names of the columns of the lines of results (depending on the language) and measuring unit on a 2nd line:
Rdg N° Sp Cy Ph Date Time Torque Angle RP
Nm dg
xxxx xx xx xx xx/xx/xx xx:xx:xx xxxxxx xxxxxx xxx
Result
1 char. <CR>
4 Reading number
1“ “
2 Spindle number
1“ “
2 Cycle number
1“ “
2 Phase number (= 2 blanks if cycle result)
1“ “
8 Date in DD/MM/YY format
1“ “
8 Time in hh:mm:ss format
2“ “
6 Torque
2“ “
6 Angle
2“ “
3 Report code
1 <LF>
In "Print at end of cycle" mode, the reading number is replaced by blanks.
Example of result:
<CR>1223 02 03 00 18/04/98 09:03:45 0030.2 0120.5 B <LF>