TECHNICAL REFERENCE MANUAL
4.7.1.2.1. IOLITEr-32xDI: Power Out: Pinout
Power out connector: pin-out (terminal block male)
PWR OUT connector (on the device): OMNIMATE Signal SL 2.50/02/90G
Mating connector (for the cable): OMNIMATE Signal BLF 2.50/02/180
Caution
PWR OUT pins are intended to supply external loads. Do not connect the external power supply
to the PWR OUT pins! It can damage the equipment.
Current limit of PWR OUT source is 2 A per module.
Current limit of the IOLITE system is 16 A!
4.7.1.2.2. IOLITEr-32xDI: Digital Input: Pinout
Digital in connector: pin-out (terminal block male)
DI connector (on the device): OMNIMATE Signal SL 2.50/09/90G
Mating connector (for the cable): OMNIMATE Signal BLF 2.50/09/180
Important
The common pin is not shared through all the 32 channels, but by groups of 8 channels.