EasyManuals Logo

Digi Connect EZ Mini User Manual

Digi Connect EZ Mini
774 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #513 background imageLoading...
Page #513 background image
User authentication Authentication groups
Digi Connect EZ Mini User Guide
513
l read-only: provides users of this group with read-only access to the WebUI and
Admin CLI.
The default is full.
n Shell access:
(config auth group test)> acl shell enable true
(config)>
Shell access is not available if the Allow shell parameter has been disabled. See Disable
shell access for more information about the Allow shell parameter.
n Serial access:
(config auth group test)> acl serial enable true
(config)>
5. (Optional) Configure captive portal access:
a. Return to the config prompt by typing three periods (...):
(config auth group test)> ...
(config)>
b. Enable captive portal access rights for users of this group:
(config)> auth group test acl portal enable true
(config)>
c. Add a captive portal to which users of this group will have access:
i. Determine available portals:
(config)> show firewall portal
portal1
auth none
enable true
http redirect
no interface
no message
no redirect_url
no terms
timeout 24h
no title
(config)>
ii. Add a captive portal:
(config)> add auth group test acl portal portals end portal1
(config)>
6. (Optional) Configure Nagios monitoring:
(config)> auth group test acl nagios enable true
(config)>

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi Connect EZ Mini and is the answer not in the manual?

Digi Connect EZ Mini Specifications

General IconGeneral
BrandDigi
ModelConnect EZ Mini
CategoryServer
LanguageEnglish

Related product manuals