64
160XT 180XT 210XT
10. Operation of the safety devices from the chassis control centre
- lift the platform slightly up from the transport position
- the outriggers must not operate in any position of the selector switch
- lift the boom and test the following:
1. emergency stop (3)
2. emergency descent; retracting the telescope (6)
3. emergency descent; lowering the boom (5 and 8)
- bring the boom to the transport position and lift the outriggers with the driving
device connected.
- the boom must not operate in any position of the selector switch
- disconnect the driving device and lower the outriggers (bring the lift to a level
position)