DWG2000E/F/G GSM/CDMA VoIP Gateway User Manual
_______________________________________________________________________________
Shenzhen Dinstar Technologies Co., Ltd.
53
from here
USA Standard:
Ringback Tone: 440,280,480,280,2000,4000,0,0 frequency: 440/480Hz on:2000ms
off:4000ms
Busy Tone: 480, 330, 620, 330, 500, 500, 0, 0 frequency: 480/620Hz, on: 500ms off:
500ms
Preferred Coders
Means the code format when Voice transfer on IP network, support PCMA, PCMU,
G.723.1 andG.729AB.
To configure dialing mode parameters
Do Not Answer GSM Incoming Call for Hotline
When the gateway get incoming call from mobile network, the module will answer the
call then start to DTMF or route to destination hotline number. While this option
enabled, the module won’t answer the call but routing to destination hotline number
till it getting answer.
Notes: Refer to Port Parameter page for Hotline configuration.
Enable PSTN Incoming Configuration
Means when call from mobile side, you can dial the feature codes (Chapter 3 Basic
Operation) to configure IP address and so on
Enable Auto Outgoing Routing
Means when call out, whether by ordinal or polling pick to Select a Channel, this
feature are generally used when use the same SIP User ID to register.
IP to PSTN One Stage Dialing