EasyManua.ls Logo

Dinstar DWG2000E - 5.5 ECC Log Tracing (Call Details); 5.6 Module Log Tracing

Dinstar DWG2000E
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DWG2000E/F/G GSM/CDMA VoIP Gateway User Manual
_______________________________________________________________________________
Shenzhen Dinstar Technologies Co., Ltd.
84
ROS#
ROS#^ada
ROS(ada)#ADA CONNECTED ...,WELCOME!
ROS(ada)#
ROS(ada)#turnon 71
Disable sip trace:
ROS(ada)#turnoff 71
5.5 How to trace ECC logs (Call Details)
Welcome to Command Shell!
Username:admin
Password:*****
ROS>en
ROS#
ROS#^config
ROS(config)#deb port all
Debug All!!.
//enable trace on all port
ROS(config)#
ROS(config)#deb port 0
Succ! Debug PortNo:0
// enable trace port 0
ROS(config)#
ROS(config)#no deb port all
ROS(config)#
ROS(config)#ex
ROS#^ada
ROS(ada)#ADA CONNECTED ...,WELCOME!
ROS(ada)#turnon 84
Disable trace:
ROS(ada)#turnoff 84
5.6 How to trace Module logs
Welcome to Command Shell!
Username:admin
Password:*****
ROS>en
ROS#^ada
ROS(ada)#ADA CONNECTED ...,WELCOME!
ROS(ada)#cmd 53 19 0 0 1