DTG M Series Maintenance Manual Initial Setup & Basic Operations
3.3 Choosing a Place for the Printer
Do not place the printer in a location under the following conditions. Doing so may cause
the product to fall over, become damaged, or cause serious injury:
o Unstable or shaky surfaces.
o Slippery, slanted or angled surfaces.
o Locations that are subject to vibration from other products.
Do not stand, or lean, on the printer or place any objects on it. Doing so may cause it to fall
over, become damaged, or cause injury.
Do not cover any ventilation holes or slots of the printer with anything at all. Doing so could
prevent the printer from ventilating and cause fire.
Keep the printer away from damp, humid or dusty areas. Failure to do so may result in
electrical shock or fire.
3.3.1 Installation Environment Requirements
Choose a place for printer installation following the requirements of the table below.
5m
2
or more, 2.6m or more is required for the width
Up to 3000Pa (450kgf/m
2
) or more
Electrical
specifications
AC 100 V - 120 V ± 10% or AC 200 V - 240 V ± 10% (auto-
switching)
18º C (64F) to 30ºC
(86F)
20% to 80%, with no
condensation
Printing accuracy warranty range
18ºC (64F) to 28ºC
(82.4F)
40% to 60%, with no
condensation
TABLE 3-1 INSTALLATION ENVIRONMENT REQUIREMENTS