7.3.2 Initializing memory
The program loads a standardized factory setting for the
sewing-program parameters,
e.g. for a new controller:
Info line:
Initializing memory
CAUTION:
Once one of these three programs has been run the parameters set
are overwritten with a standardized factory setting.
For this reason this program section can only be run after the entry of
code number “25483”.
–
Press OK to run the test program.
The code-number entry box appears in the display.
–
Enter code number “25483” on the decimal keypad.
Once the correct code number has been entered the display
switches to the four parameters listed below.
If an incorrect code number is entered, the display switches to the
machine-specific parameter screen.
Initializing the machine parameters
Initializing pocket programs
Initializing pocket sequences
Initializing all programs and parameters
Hint:
After initialization, the machine parameters (RST + F1)mustbe
rechecked.
48