Caution: danger of injury
During template scanning the feed clamps move back
and forth several times.
Do not reach into the path of the feed clamps.
–
Press function key “F5”.
The straight-pocket template is scanned.
The scanned parameters appear in the display. They are
automatically passed to the controller.
789
Info line:
Aligning light barriers
–
Press “9”.
The flap clamp opens.
–
Remove the straight-pocket template.
Insert the slanting-pocket template 4 so that line 5 points to the left
needle and is parallel to the right feed clamp.
–
Press “9”.
Theflapclampcloses.
–
Stick the left, proud side of the template to the clamp with a strip of
adhesive tape 3.
–
Press function key “F2”.
The slanting-pocket template is scanned.
The scanned parameters appear in the display. They are
automatically passed to the controller.
–
Press “9”.
The flap clamp opens.
–
Remove the slanting-pocket template.
–
Press function key “F1” to terminate the test program.
–
Push feed clamps backwards by hand.
–
Swivel folding station back and lock in place.
–
Press the “RST” key or switch the machine off and on again.
54