Error number Meaning Remedy
Error 3121 Insufficient or missing compressed
air pressure
Increase the flow or stabilize the air
pressure
Error 3210
Thread breakage
Re-thread the machine again
Error 3220
Empty bobbin
Insert full bobbin
Error 3500
-
3507
3520
-
3530
3540
3545
3721
3722
Error Command Interpreter /
Motor synchronization
Internal error
- Switch the machine off/on again
- Software update
- Inform the DA-Service
Info 4301 No dongle plugged in
Info 4304 Wrong dongle type
Error 6551
-
6554
6651
-
6653
6751
-
6761
Error machine head position /
AD-Converter / Processor error
Internal error
- Switch the machine off/on again
- Software update
- Inform the DA-Service
Error 6952 Error step motor driver
Internal error
- Switch the machine off/on again
- Software update
- Inform the DA-Service
Error 7200 Error in the CAN - Module
Knife-bracket unit (AC001).
No module has been recognized at
the address.
Check cable, jumper setting, power supply
Error 7201 Error in the CAN - Module
Knife-bracket unit (AC001).
Power-fail.
Check cable, jumper setting, power supply
Error 7202 Error in the CAN - Module
Knife-bracket unit (AC001).
Power amplifier overheating.
Check cable, jumper setting, power supply,
motors and power amplifier.
Error 7209 Error in the CAN - Module
Knife-bracket unit (AC001).
Wrong module has been recognized
at the address.
Check jumper setting/DIP switches
Error 7210 Error in the CAN - Module
Transport unit (AC101).
No module has been recognized at
the address.
Check cable, jumper setting, power supply
Error 7211 Error in the CAN - Module
Transport unit (AC101).
Power-fail.
Check cable, jumper setting, power supply
Error 7215 Error in the CAN - Module
Transport unit (AC101).
Output: Overload / Short circuit
Check the output cable / plug.
Error 7219 Error in the CAN - Module
Transport unit (AC101).
Wrong module has been recognized
at the address.
Check jumper setting/DIP switches
Error 7260 General error in the CAN - Modules
Check cable
Error 7551
-
7555
7558
7559
Communication Control Panel
interface
- Internal error
- Switch the machine off/on again
- Software update
- Inform the DA-Service