Maintenance - 2000h
4812160801_D.pdf2018-12-17
Alternator belt - Checking tension - Change
Fig. Alternator viewed from the front
1. Mounting screw
2. Mounting screw
3. Alternator belt
1
2
3
Switch off the engine, disconnect the power and
switch on the emergency brake button.
Switch off the engine, disconnect the power and
switch on the emergency brake button.
Undo the two hexagonal socket screws (1) and (2).
Bend off the old alternator belt and replace with a new
Press the alternator across so that the alternator belt
is tensioned to the measurement given below.
When the alternator belt (3) can be pressed by hand in
around 10 mm halfway between the pulleys, it is
correctly tensioned.
Tighten first screw (1) and then screw (2). Check that
the belt still has the correct tension after tightening.
Water tank - Cleaning
Fig. Bay under the floor
1. Drainage tap
2. Water filter
3. Water pump
1
2
3
Keep in mind that there is a risk of freezing in
winter. Drain the tank, pump and lines.
Keep in mind that there is a risk of freezing in
winter. Drain the tank, pump and lines.
Drain the tank through the drainage tap (1) alongside
the filter.
Clean the tanks with water and a suitable detergent for
plastic surfaces.
Clean the water filter (2). Fill the tank with water and
check that the sprinkler functions.
The water tanks are made of plastic
(polyethylene) and are recyclable.
The water tanks are made of plastic
(polyethylene) and are recyclable.