Maintenance measures - 500 h
4812160801_D.pdf2018-12-17
Maintenance measures - 500 h
Every 500/1500..... hours of operation (every six
months)
Park the roller on a level surface.
The engine must be switched off and the
parking brake activated when checking or
adjusting the roller, unless otherwise specified.
Park the roller on a level surface.
The engine must be switched off and the
parking brake activated when checking or
adjusting the roller, unless otherwise specified.
Ensure that there is good ventilation (air
extraction) if the engine is run indoors. Risk of
carbon monoxide poisoning.
Ensure that there is good ventilation (air
extraction) if the engine is run indoors. Risk of
carbon monoxide poisoning.
Ensure that the engine cover is fully open when
work is being carried out under it
Ensure that the engine cover is fully open when
work is being carried out under it
Hydraulic fluid cooler - Cleaning
Fig. Engine compartment
1. Hydraulic fluid cooler
1
Clean the hydraulic fluid cooler’s cooling flanges,
ideally with compressed air. Blow the cooler clean by
blowing air from the inside outwards.
Wear gloves and eye protectors when working
with compressed air.
Wear gloves and eye protectors when working
with compressed air.
83