2 Engineering
2.9 DS7-SWD and PKE motor-protective circuit-breakers
DS7 Soft starter 09/16 MN03901001Z-EN www.eaton.com 39
2.9 DS7-SWD and PKE motor-protective circuit-breakers
DS7-SWD soft starters can also provide the following functions when used
together with a PKE motor-protective circuit-breaker:
Protecting the DS7 soft starter against overload
adjustable current limitation,
ZMR overload relay function (in the event of an overload, the DS7 soft
starter will switch off the load, instead of the PKE motor-protective
circuit-breaker doing so)
Currents readable via SmartWire-DT
After a motor protective device has tripped, the soft starter and
the protective device cannot be switched on again until it has
cooled down. The reset depends on the temperature.
Figure 21: Motor-starter combination: DS7-SWD and PKE
Only PKE trip blocks (PKE-XTUWA-32, PKE-XTUA-…) should be
used for motor protection in combination with DS7 soft starters.
PKE trip block PKE-XTUCP-… for system protection must not be
used in combination with a soft starter DS7! In combination
with SmartWire-DT this can cause false tripping.