8 SmartWire-DT
8.10 SmartWire-DT diagnostics
214 DS7 Soft starter 09/16 MN03901001Z-EN www.eaton.com
8.10.4 SmartWire-DT diagnostic LEDs
The following table shows the information that can be determined based on
the SmartWire-DT diagnostic LEDs.
Table 44: SmartWire-DT diagnostic LED indications
Switching command present
For the orange SmartWire-DT diagnostic LED, the “switching command
present” message means the following:
Profiles 1, 2, 3: DS7 Start/Stop = 1.
Profiles 4, 5, 6, 10:EN_Set and EN_Op = 1.
Profiles 7, 8, 9, 11:OnOff =1, Off2 =1, Off3 = 1, EN_Op = 1,
EN_Ramp = 1, Freeze = 1, EN_Set = 1, Ctl_PLC = 1.
Diagnostics
If the “Diagnostics” message appears, input byte 0, bit 4 (DIAG) will be set
to 1 as well. The message has the following meaning:
Profiles 1 to 9: There is an advanced diagnostic alarm for soft starter DS7
or motor-protective circuit-breaker PKE.
Profiles 10 and 11: There is an advanced diagnostic message for the
DS7-SWD soft starter
Color LED Switch
command
Position
1-0-A switch
Status Status signal
off No power supply
Orange Available A Continuous light Device is operating error-free.
flashing (3 Hz) Diagnostics
Green not available 1 or
0 or
A
Continuous light Device is operating error-free.
flashing (1 Hz) addressing process in progress
After powering on the gateway
After pressing the configuration button on the gateway
Module not present in current configuration
invalid type
flashing (3 Hz) Diagnostics