OPERATION
PREVENTATIVE MAINTENANCE
FIGURE 3-13
FREQUENCY:
Loose debris removal from the nger panel outer plates should occur MONTHLY or as
needed. Full nger assembly removal and a thorough deep clean should occur SEMI-
ANNUALLY or as needed.
METHOD:
Remove the oven conveyor belt and nger panel assemblies from the oven chamber, see CONVEYOR
BELT & FINGER PANEL REMOVAL AND INSPECTION in the OVEN OPERATION section for further
details of how to do this.
Use a stiff bristle brush to remove debris from the top and bottom nger outer plates.
Use a solution of mild dish detergent and warm water for normal cleaning if required.
Wipe the surface with a dampened soft cloth.
If the nger assemblies have been removed from the oven, ensure they are dry before replacing them in
the order they were removed.
CAUTION:
DO NOT apply solvents of any kind to the COLUMNATING PANEL.
Solvents and pressure washing may be used to clean FINGER HOUSING and FINGER COVERS only.
AREA OF OVEN:
Inside the oven cooking chamber.