SPECIFICATIONS
US DOMESTIC EXPORT MODELS
MODEL VOLTS (AC) HERTZ AMPS VOLTS (AC) HERTZ AMPS
1830 120 VAC 1Ф 60 5.5~9.5 220/230/240 VAC 1Ф 50 3.0
2440 120 VAC 1Ф 60 5.5~9.5 220/230/240 VAC 1Ф 50 3.0
3240 120 VAC 1Ф 60 5.5~9.5 220/230/240 VAC 1Ф 50 3.0
2460 120 VAC 1Ф 60 5.5~9.5 220/230/240 VAC 1Ф 50 3.0
3260(S) 120 VAC 1Ф 60 5.5~9.5 220/230/240 VAC 1Ф 50 3.0
3860 120 VAC 1Ф 60 5.5~9.5 220/230/240 VAC 1Ф 50 3.0
4460(S) 120 VAC 1Ф 60 5.5~9.5 220/230/240 VAC 1Ф 50 3.0
3270 120 VAC 1Ф 60 5.5~9.5 220/230/240 VAC 1Ф 50 3.0
3870 120 VAC 1Ф 60 5.5~9.5 220/230/240 VAC 1Ф 50 3.0
PER OVEN:
A separate 20A (US Domestic) -OR- 16A (Export) circuit breaker must be provided for EACH oven deck.
All electrical outlets should be installed on the control cabinet side (right hand side of oven position).
Electrical connections must be accessible when the ovens are in their installed position.
Electrical connection must meet all local code requirements.
To prevent damage to the oven and personal injury or death, the voltage, phase and
grounding of the electrical supply must be inspected and veried prior to energizing.
WARNING
The intended electrical supply MUST be veried at the connection point (electrical outlet
or electrical junction box) prior to connecting the oven. Voltage exceeding 10% of the
rated voltage will result in damage to the oven components and WILL NOT BE COVERED
UNDER WARRANTY.
CAUTION
IMPORTANT
North America (Domestic) appliances include an attached 14/3-AWG NEMA-15 cord set. Ensure that the
retaining clip is correctly installed over the corded receptacle during installation. This cord must not be altered
in anyway.
Export (World) appliances shall be connected using a gland and a tted cord set (not supplied). Connections
are to be made directly to the EM lter. Ensure that the earth ground is properly terminated to the marked
bonding point.
GAS OVEN ELECTRICAL SPECIFICATIONS
This appliance operates using an inverter and inverter duty motor. GFCI/RCCB
devices are not recommended. False or “nuisance” trips are possible at start-up and
during operation. In the event a GFCI/RCCB is required by the local electrical code,
a quality GFCI/RCCB of the appropriate type must be selected. EDGE recommends
Siemens panel mounted GFCI Breakers 20A (USA) / RCCB (B Type) 16A breaker
protection devices (EXPORT).

Table of Contents

Other manuals for Edge EDGE-1830

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge EDGE-1830 and is the answer not in the manual?

Edge EDGE-1830 Specifications

General IconGeneral
BrandEdge
ModelEDGE-1830
CategoryOven
LanguageEnglish

Related product manuals