2. Verify that the tow cable is properly connected and attached to the towfish, and then connect the
tow cable to the SEA CABLE connector.
3. Connect the LCD monitor to the MONITOR connector.
4. Connect the trackball to a back-panel USB connector.
5. Connect the keyboard to a back-panel USB connector.
6. If a navigation system will be used, connect the navigation system output to the COM 1 connector.
7. If an external source will be used to trigger the 4205 701-DL with 2U CPU, connect the trigger
output of this source to the EXT TRIG connector.
8. Connect AC power cord for 2U Processor and 701DL to VAC INPUT connector and AC power source.
9. Connect an AC power cord to the LCD monitor and the AC power source.
4.6.3.5 Connecting to the Starmux III DL
Note: The Starmux IV has replaced the Starmux III. This section is included
only to support systems sold with the Starmux III.
Refer to subsection STARMUX III CONTROLS, INDICATORS AND CONNECTIONS for the location of the connectors
while performing the steps below:
1. Verify that the Starmux III DL is not connected to AC power.
2. Verify that the tow cable is properly connected and attached to the towfish, and then connect the
tow cable to the SEA CABLE connector.
3. Connect the Ethernet patch cable to the DATA connector of the Starmux III Digital Link and to the
ethernet connector of the computer (2U, Getac Semirugged, or user-supplied). This cable may be
extended up to 100 feet using a Category 5 Ethernet crossover or straight patch cable.
4. Set the IP address of your computer to 192.9.0.nnn, where nnn is any integer from 1 to 100, except
for 192.9.0.22, 192.9.0.225, 192.9.0.101, and 192.9.0.102, which are reserved.
5. If a navigation system will be used, connect the navigation system output to an available serial
communications port.
6. If an external source will be used to trigger the Starmux III Digital Link, connect the trigger output
of this source to the SYNC connector.
7. Connect the AC power cord to the LINE VAC connector and the AC power source.