3.2 Performance data
Table 3
Performance data
Pump
Characteriscs
Typical peak
pumping speed
Ulmate (sha seal
purge only)
Maximum connuous in‐
let pressure
Units
m
3
/h
mbar mbar
EXS750 740
< 1 x 10
-2
1000*
EXS450 450
< 1 x 10
-2
1000*
* Speed may be limited.
3.3 Loading da
t
a
Refer to Installaon drawings on page 29 for the centre of gravity posions for dry
pumping systems. The loading data in Table: Loading data is for dry pumping systems
with oponal levelling feet and castors.
Table 4
Loading data
Pump
Load at levelling foot posion (kg)
1 2 3 4
EXS750 160 180 180 160
EXS450 130 142 142 130