Table 19
DP clean sequence
Sequence Descripon
Dry pump clean
Purge gas or the solvent uid is admied into the pump for a
congurable me (recommended 20 minutes).
Pump speed during the dry pump clean is congurable
(recommended 40 Hz).
Keep gas purges on.
Pump is not able to go onprocess unl the cycle has
completed.
The DP clean high ow purge and solvent ush procedures can be run as oen as
required.
6.7.1 High ow purge and solvent ush
Operaon instrucon of high ow purge and solvent ush is provided together with the
kit, contact us.