9. Storage
Drain the c
ooling water from the dry pumping system. If transporng or storing it in
condions where the cooling water could freeze, refer to Draining the cooling water on
page 58. Failure to observe the instrucons could result in the cooling water freezing in
the dry pumping system and damage to the pumps and/or the cooling water pipelines.
Store the dry pumping system as follows:
1. Follow the procedure set out in Relocate the dry pumping system for maintenance
on page 57.
2. Store the dry pumping system in clean dry condions unl required.
3. If the pump is to be stored for longer than six weeks, it must be manually rotated
every 14 days or less. Contact us for details.
4. When required for use, prepare and install the dry pumping system as described in
Installaon on page 27 of this manual.
07/2021 - ©Edwards Limited
Page 71A41870880_A
A41870880_A - Storage