3. Technical data
3.1 General t
echnical data
Table 1
General technical data
Item
Descripon Rang Units
Operang condions
In
tended use Indoor
Ambient temperature range:
Operang
St
orage
5 to 40
-45 to 55
°C
°C
Maximum relave humidity:
80% for temperatures up to 31 °C
decreasing linearly to 50% relave
humidity at 40 °C
Maximum operang altude 2000 m
Maximum operang back
pressure
1.2 bar(a)
Polluon degree 2 (IEC 61010)
Materials in contact
with the process gas
Pump, sha and rotors Cast SG iron
Seals PTFE and uoroelastomer
Gas system
Carbon steel, brass, PTFE and uo‐
roelastomer
Degree of protecon
Hazardous electrical sub sys-
tem
IP21D (IEC60529)
Lubricaon Oil type
PFPE Drynert 25/6 (recommended)
Fomblin
®
25/6 (alternave)
Krytox
®
1525 (alternave)
Table 2
General technical data
Characteriscs
EXS750 EXS450 Unit
Body dimensions length x width x
height*
1650 x 567 x 642 1265 x 567 x 642 mm
Mass (excluding packaging) 650 540 kg
Noise level (at ulmate with a piped ex-
haust)
< 70 dB(A)
Typical vibraon level at inlet < 1.5 mm/s
Pump inlet ange (bolted) ISO100 -
Exhaust gas outlet
NW50
-
Lubricant volume 2.8 1.8 litre
* Refer to Inst
allaon drawings on page 29.
Refer to Connect the dry pumping system to the vacuum/exhaust system on page 35
for informaon relang to the exhaust size and length for EXS dry pumping systems.
07/2021 - ©Edwards Limited
Page 15A41870880_A
A41870880_A - Technical data

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards EXS Series and is the answer not in the manual?

Edwards EXS Series Specifications

General IconGeneral
BrandEdwards
ModelEXS Series
CategoryWater Pump
LanguageEnglish

Related product manuals