Fault CrST ‐ Cannot reset
Cause The drive received a fault reset command when a run command was acve.
R
emedy Turn o the run command then de-energise and re-energise the drive.
Fault EF ‐ FWD/REV Run command input error
Cause A forward command and a reverse command were input at the same me for
longer than 0.5 second.
Remedy Examine the forward and reverse command sequence and correct the problem.
Fault HCA ‐ High current alarm
Cause The load is too heavy.
Remedy Decrease the load for applic
aons with r
epeve starts and stops.
Contact us.
Cause The acceleraon
me is too short.
Remedy Contact us.
Fault oH ‐ Heatsink overheat
Cause The airow is not enough ar
ound the driv
e.
Remedy Check cubicle fan.
Cause The drive internal fan has stopped.
Remedy Check whether it should be replaced.
Fault dWAL ‐ Warm up nish
Cause Warm up completed.
Remedy The pump has been warmed up completely, the inlet valve must be opened
manually
.
Fault dWA2 ‐ High temperature
Cause The stator reaches 120 °C which is very hot for stator.
Remedy Check cooling water.
07/2021 - ©Edwards Limited
Page 70A41870880_A
A41870880_A - Fault nding

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards EXS Series and is the answer not in the manual?

Edwards EXS Series Specifications

General IconGeneral
BrandEdwards
ModelEXS Series
CategoryWater Pump
LanguageEnglish

Related product manuals