WARNING:
We r
ecommend the use of water and diluted Locte® 7840 or Locte® Natural Blue®
when performing a solvent ush procedure. It is your responsibility to assess
whether the Locte® 7840/Natural Blue® is compable with the applicaon. For
more informaon refer to the Locte® MSDS and technical datasheet. The
manufacturer states that the Locte® 7840 and Locte® Natural Blue® are not
recommended for use in pure oxygen and/or oxygen rich systems and should not be
selected as a sealant for chlorine or other strong oxidizing materials.
For queries about the solvent compability, contact our applicaons specialists.
WARNING:
Hot st
eam and liquid will exit the pump during the solvent ush procedure. Ensure
that the exhaust is piped away safely and solvents are disposed of in accordance with
the local and naonal safety and environmental requirements.
CAUTION:
If an inert gas is used in place of a
tmospheric air for the DP clean purge gas, ensure it
is regulated to atmospheric pressure otherwise the DP clean process may not work
properly and may cause damage to the pump.
The high ow pur
ge and solvent ush procedures are performed by a single assembly
which is supplied as an oponal kit. The actuang valve is operated pneumacally.
Ensure that the pneumac gas supply meets the specicaon given in DP clean high ow
purge/solvent ush (opon) on page 23.
Use a 3/8 inch compression ng (not supplied) to connect the pneumac supply to the
dry pumping system. For the pump‑only systems, refer to Figure: DP clean assembly for
the pump only systems.
The pneumac regulator is pre-set to 50 ± 5 psig in the factory and does not need to be
adjusted. The pneumac regulator is shown in Figure: DP clean assembly for the pump
only systems, for the pump‑only systems.
To use an inert gas in place of atmospheric air as the DP clean purge gas, remove the air
lter and in its place connect up the inert gas supply. For pump‑only systems, refer to
Figure: DP clean assembly for the pump only systems. Refer to DP clean high ow purge/
solvent ush (opon) on page 23 for informaon about ngs and typical purge gas
ows.
When only performing a high ow purge procedure, a solvent sucon pipe will not be
needed. When performing a solvent ush, t a solvent sucon pipe only when ready to
perform the DP clean procedure. For pump‑only systems, refer to Figure: DP clean
assembly for the pump only systems.