03-2009 SOI/DT-mdm FCPD-dp Quality-fz 23/91 599 70 56-70
YES
Access the diagnostic cycle and duct water through all the compartment (phases 2,3,4,5)
Is water ducted through all the compartments?
E13: Water leakage
E13
Overall maximum water fill time exceeded (the sum of all the water fills between one drain
phase and the next, to avoid exceeding the maximum volume)
E13
Tests to be performed:
YES
YES
NO
YES
Position the drain circuit correctly and restart the
diagnostic cycle to check for further alarms.
NO
Repair the hydraulic circuit of the pressure
switch and restart the diagnostic cycle to check
for further alarms.
Replace the circuit board and restart the diagnostic cycle to check for further alarms.
Is the drain hose positioned
correctly so as not to create the
siphon effect? (fig.1)
Is the hydraulic circuit of the
pressure switch efficient
(leaks/blockage)? fig.2
NO
Check that the tap is open, that the mains
water pressure is sufficient and that the hoses
are correctly connected and not kinked.
Do any or all the solenoids fail to function?
YES
NO
Replace the solenoid and restart the diagnostic
cycle to check for further alarms.
Is the ohmic resistance of the solenoid about
3.5÷4.5 KΩ? (Measure directly on the solenoid
valve without wiring) -see fig. 3-
NO
YES
NO
Replace or repair the wiring and restart the
diagnostic cycle to check for further alarms.
Re-attach the connector and measure about 3.5
–4.5 KΩ on the solenoid wiring connector
(circuit board side) see fig. 4-: across J9-3 and
J9-1 (washing) and across J9-6 and J9-4
(prewash). Is the solenoid valve wiring OK?
YES
Replace the circuit board and restart the
diagnostic cycle to check for further alarms.
NO
Repair the hydraulic circuit and restart the
diagnostic cycle to check for further alarms.
Is the hydraulic circuit efficient
(leaks)?
If there are traces of burning on the circuit
board, refer to page 90