03-2009 SOI/DT-mdm FCPD-dp Quality-fz 33/91 599 70 56-70
Start the diagnostic
cycle and set the
phase 6.
Is the motor turning
and the drum not
moving?
YES
Empty the machine.
Verify the air trap
system and the
pressure switch
hose. Is the system
free?
-(see fig.2)-
Clean the air trap
system and/or the
pressure switch
hose and run again
the diagnostic cycle.
Change/refit the
drive belt and run
again the diagnostic
cycle to check for
further alarms.
YES
Replace the
analogic pressure
switch and run again
the diagnostic cycle
to check for further
alarms.
E38: Pressure chamber blocked
E38
The analogic pressure switch is not able to measure any variation of the water level for at
least 30-sec. during drum movement.
E38
Tests to be performed:
Fig.2
NO
NO