EasyManua.ls Logo

Electrolux EWM2100 - Table of Contents

Electrolux EWM2100
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
03-2009 SOI/DT-mdm FCPD-dp Quality-fz 3/91 599 70 56-70
Contents
1.1
Purpose of this manual ....................................................................................................................... 5
1.2 Procedure ........................................................................................................................................... 5
2 WM APPLIANCES CONTROL PANELS ................................................................................................... 6
3 WD APPLIANCES CONTROL PANELS ................................................................................................... 7
4 DIAGNOSTIC SYSTEM............................................................................................................................. 8
4.1 ACCESS TO THE DIAGNOSTIC CYCLE .......................................................................................... 8
4.2 Exiting diagnostics mode .................................................................................................................... 8
4.3 PHASES OF THE DIAGNOSTIC CYCLE .......................................................................................... 9
5 ALARMS .................................................................................................................................................. 11
5.1 Displaying the alarms to the user ..................................................................................................... 11
5.2 Reading the alarm codes.................................................................................................................. 12
5.2.1 Alarm displaying....................................................................................................................... 12
AEG Version: ........................................................................................................................................... 12
5.2.2 Examples of alarm display .......................................................................................................13
5.2.3 Operation of alarms during diagnostics ................................................................................... 13
5.3 Rapid reading of alarm codes........................................................................................................... 14
5.4 Cancelling the last alarm .................................................................................................................. 14
5.5 TABLE OF ALARMS......................................................................................................................... 15
5.6 Notes concerning certain alarm codes ............................................................................................. 18
6 THE DIAGNOSTIC PROGRAMME CANNOT BE ACCESSED .............................................................. 19
6.1.1 All LEDs on the circuit are board switched off ......................................................................... 19
6.1.2 Some of the LEDs of the circuit board light.............................................................................. 19
7 TROUBLESHOOTING ACCORDING TO ALARM CODES .................................................................... 20
E11: Difficulty in filling water during washing phase ............................................................................ 20
E12: Difficulty in filling water during drying phase................................................................................ 22
E13: Water leakage.............................................................................................................................. 23
E21: Difficulty in draining...................................................................................................................... 25
E22: Difficulty in draining water during drying phase ...........................................................................27
E23: Malfunction of the component (triac) that controls the drain pump ............................................. 29
E24: «Sensing» circuit of the component (triac) that controls the drain pump faulty........................... 30
E35: Water level too high ..................................................................................................................... 32
E38: Pressure chamber blocked .......................................................................................................... 33
E3A: Problems with “Sensing” circuit of the heating element relay ..................................................... 34
E41: Door open (3-contact device)....................................................................................................... 35
E41: Door open (4-contact device)....................................................................................................... 37
E42: Problems with door aperture (3-contact device).......................................................................... 39
E42: Problems with door aperture (4- contact device)......................................................................... 41
E44: Door closure «sensing» circuit faulty ........................................................................................... 45
E45: Problems with the «sensing» circuit of the triac that actions the door interlock .......................... 45
E51: Motor power triac short-circuited ................................................................................................. 46
E52: No signal from the motor tachometric generator (first part)......................................................... 47
E52: No signal from the motor tachometric generator (second part)................................................... 49
Procedure for checking the commutator motors .................................................................................. 50
E53: Problems with the "Sensing" circuit of the triac which powers the motor .................................... 51
E54: Motor relay contacts sticking........................................................................................................ 52
E61: Insufficient heating during washing.............................................................................................. 53
E62: Overheating during washing (version WM).................................................................................. 54
E62: Overheating during washing (version WD) .................................................................................. 55
E66: The contacts of the heating element power relay are always closed (version WM).................... 56
E66: The contacts of the heating element power relay are always closed (version WD) .................... 57
E68: Washing heating element leaks current (version WM) ................................................................ 58
E68: Washing heating element interrupted (version WD).................................................................... 59
E69: Washing heating element interrupted (version WM) ................................................................... 60
E69: Washing heating element interrupted (version WD).................................................................... 61
E71: NTC washing sensor faulty .......................................................................................................... 62
E72: Drying NTC sensor on condenser faulty......................................................................................63
E73: NTC sensor on drying duct faulty ................................................................................................ 64
E74: NTC sensor wrongly positioned................................................................................................... 65
E82: Error in reading the RESET/OFF position of the programme selector ........................................ 66
E83: Error in reading the programme selector code ............................................................................ 67
E91: Communication error between user interface and main board.................................................... 68
E92: Protocol incongruence ................................................................................................................. 68

Table of Contents