03-2009 SOI/DT-mdm FCPD-dp Quality-fz 75/91 599 70 56-70
NO
YES
NO
NO
NO
NO
YES
YES
YES
YES
ED2 ED2: Drying heating element 1 faulty ED2
Tests to be performed:
If there are traces of burning on the
circuit board, refer to page 90
Check if the belt of the motor
fan is correctly fitted (fig. 21)-
Is the bel OK?
Fit the belt and reset the manually reset thermostat. To reset
the thermostat push the red button (see fig. 23). Restart the
diagnostic cycle to check for further alarms.
Perform phase 9 of the
diagnostic cycle and
check that the motor fan
starts to run after 15 sec.
Does the motor fan
function correctly?
Demount and clean the condenser, reset the manually reset
thermostat. To reset the thermostat push the red button (see
fig. 23). Restart the diagnostic cycle to check for further
alarms.
Check for possible clogging of
the condenser (see fig. 24). Is
the condenser OK?
Measure the value of the
motor fan winding (Ω)
across terminals J8-2 ÷
J8-1 of the wiring
connector (see fig. 22).
Is the value correct as
described in Tab. 3?
Detach the connectors
and measure the
winding value (Ω)
directly across motor
fan terminals. Is the
value correct as
described in Tab. 3?
Replace the motor fan, reset the manually reset thermostat.
To reset the thermostat push the red button (see fig. 23).
Restart the diagnostic cycle to check for further alarms.
Replace the wiring and
reset the manually reset
thermostat. To reset the
thermostat push the red
button (see fig. 23).
Restart the diagnostic
cycle to check for further
alarms.
Replace the WD board,
reset the manually reset
thermostat. To reset the
thermostat push the red
button (see fig. 23).
Restart the diagnostic
cycle to check for further
alarms.
Continues at page 77