Chapter 6 Parameter Descriptions 71
If the door has reached the CD location limit, this protection signal is
ineffective.
6, 7: Normally open/closed input for OD location limiting
In OD process under speed control, the drive will take actions of OD location
limiting after this signal is enabled.
8, 9: Normally open/closed input for CD location limiting
In CD process under speed control, the drive will take actions of CD location
limiting after this signal is enabled.
10, 11: Phase A/B PG signal input (only X1 and X2)
Enable the terminal as inputting PG signal to achieve close loop vector
control or distance control. Only F097 and F098 can be set so.
12,13: Normally open/closed input for OD speed changing
In OD process under speed control 1, the elevator door starts low speed
operation in ending phase after the normally open/closed input for OD speed
changing is enabled.
14, 15: Normally open/closed input for CD speed changing
In CD process under speed control, the elevator door starts low speed
operation in ending phase after the normally open/closed input for CD speed
changing is enabled.
16~18: Terminal for inputting MS speed operation signal
Through the ON/OFF combination of the terminals, up to 8 levels of speed
can be defined, and these speed levels can be set by F055~F062
respectively.
19: Terminal for inputting OD prohibition signal
OD command will not be executed if this signal is enabled.
20: Terminal for inputting torque-maintaining prohibition signal
In CD/OD torque-maintaining process, the drive will maintain the 0 torque if
this signal is enabled.
21: Low speed OD/CD enabling signal input
If this signal is enabled, the motor operates at low speed according to the
speed set by F005.
22, 23: Normally open/closed input for locking signal
TD3200 Variable Speed Drive for Elevator Door Control User Manual